2019年8月9日,CENELEC共发布了EN 60335-1:2012的三份修订标准。采纳了IEC60335-1:2010的2013和2016年修订版、增加部分的特殊要求,使之与IEC60335-1:2010更好地衔接。EN版本针对元器件的标准要求也进行了更新。
- 强制时间:制造商需在2021年7月30日前将产品符合标准的zui新要求。
- EN 60335-1在用标准:EN 60335-1: 2012+A11: 2014+A13: 2017
- EN 60335-1升级后zui新标准:
EN 60335-1: 2012+A11: 2014+A13: 2017+A1: 2019+A14:2019+A2: 2019
EN 60335-1升级zui新标准的新增条款:(注:特别留意以下红色加粗部分)
1 标准:EN 60335-1: 2012/A1: 2019
(1)生效日期:2019年11月9日
强制日期:2021年7月30日
(对应于IEC 60335-1: 2010/A1: 2013)
该标准基于原EN 60335-1: 2012+A11: 2014+A13: 2017进行更新
(2)相应变化
- 11.8 In Table 3 delete footnotes za, zb, zc, zd.
- 24.1: Components shall comply with the safety requirementsspecified in the relevant EN standards as far as they reasonablyapply.
- Plugs and socket-outlets and other connecting devices ofinterconnection cords shall not be interchangeable with plugs andsocket-outlets listed in IEC/TR 60083 or IEC 60906-1 or withconnectors and appliance inlets complying with the standard sheetsof EN 60320-1, if direct supply to these parts from the supplymains could give rise to a hazard. When an EN standard does notexist for a component, there are no additional tests specified.
2 标准:EN 60335-1: 2012/A14: 2019
(1)生效日期:2019年11月9日
强制日期:2021年7月30日
该标准基于原EN 60335-1: 2012+A11: 2014+A13: 2017+A1: 2019进行更新
(2)相应变化:
- 7.10: Add the text after the first paragraph of the addition(seestandard).
- 8.1.1: Replace the first sentence of the replacement of the3rd;
- 8.1.3: Add the text “, test probe 18” after “test probe B,”.
- 20.2: In the second paragraph replace the word “movable” by“moving” and replace “main function” by “working function”.
- 22.12: Other parts that are intended to be detached during use,maintenance or cleaning (examples are batteries, battery covers,lids, attachments, steam nozzles) are not considered as partsproviding a similar function as handles, knobs, grips, levers.
- 22.17: This is not applicable to built-in appliances.
- 24.1: NOTE Z3 For details of plugs used in CENELEC countrieslisted in IEC TR 60083 see Annex ZH.
- 25.1: Plugs and pins for insertion into socket outlets shallfollow the relevant standards sheets in Annex ZH.
- 25.6: Delete the addition.
- 25.25: Dimensions of the pins and engagement face of plugs ofappliances that are inserted into socket-outlets are to be inaccordance with the dimensions of the relevant plug standard. NOTEZ1 Common plugs and socket-outlets types in CENELEC countries asshown in Annex ZH.
- 32: Delete in the third paragraph “EN 50366 or”.
3 标准:EN 60335-1: 2012/A2: 2019
(1)生效日期:2019年11月9日
强制日期:2021年7月30日
(对应于IEC 60335-1: 2010/A2: 2016)
基于原EN 60335-1: 2012+A11: 2014+A13: 2017+A1: 2019+A14: 2019进行更新
(2)相应变化
- 7.10: Delete the paragraphs starting with “Devices used tostart/stop….” until the end of the requirement “……by vulnerablepersons.”. This includes Notes Z1 and Z2.
- 7.12: Delete the sub clause.
- 7.14: Delete Note Z1.
- 22.12: Delete Note Z1.
- 24: Type S2 and S3 capacitors according to EN 60252-1 are notrequired to undergo the testing as required by 30.2.2 and30.2.3.1.
- 25.7: Delete the existing text starting “Halogen freethermoplastic……..” until ”……..designation H07ZZ-F). “.