直插式电源适配器申请UL 1310 Class 2 unit 须注意下述二项要求:
1、 若包含CUL
依据CSA标准 CAN/CSA-C22.2 NO.233-M91 章节 4.13.1 Open-CircuitSecondary Voltage “The open-circuit secondary voltage shall not bemore than 30Vrms (42.2V peak or DC) ”
2、 间距要求,依条文22.1, 22.2如下
22.1 Spacings between live parts of opposite polarity, between liveand dead metal parts, and between live parts and a metal enclosure,shall be as specified in Table 22.1 or Table 22.2, as appropriate.If a live part is not rigidly secured in position by a means otherthan friction between surfaces, or if a movable dead metal part isin proximity to an uninsulated live part, the construction shall besuch that at least the minimum spacings will be maintained.
Exeption No.1: Spacings between traces on a printed wiring boardneed not comply with Tables 22.1 and 22.2 if the printed wiringboard complies with the abnormal operation test in 38.7.1 – 38.7.5.See also 20.3. The re specified in 20.3 and 38.7.1 –38.7.5 do not substitute for the minimum requied spacings betweenthe printed wiring board foils and dead metal parts or the spacingsbetween the primary and secondary foils of the printed wiring boardas specified in Table 22.1 or 22.2.