产品详情
SIMATICET 200 为所有应用提供完美解决方案
SIMATICET 200 ??????? I/O???????????????????????????????????????????????????????????????????
ET200????????????????????????????????????????????????????????/???? CPU????????????????????????????????????????????????
??PROFIBUS ? PROFINET ?????????????????????? SIMATIC ???? HMI?????????????????????????????
PROFINET
PROFINET??????????????????????? (IEC 61158/61784)?
PROFINET ????????????????IO ????????IO????????????????????????????????? PROFINET ???? IEEE 802.3???????????????????????????
???PROFINET????????????????????????? Web ???? FTP ? IT??????????????????????????????????? PROFIBUS ?AS-Interface????????????????
6ES7321-1BH02-0AA0 6ES7 321-1BH02-9AJ0
6ES7321-1BH10-0AA0 6ES7 321-1BH50-0AA0 6ES7 321-1BH50-9AJ0
开入模块(16点,24VDC)开入模块(16点,24VDC)组合件
(6ES7321-1BH02-0AA0+6ES7 392-1AJ00-0AA0)
开入模块(16点,24VDC)开入模块(16点,24VDC,源输入) 开入模块(16点,24VDC,源输入)组合件 (6ES7321-1BH50-0AA0+6ES7 392-1AJ00-0AA0)
6ES7321-1BL00-0AA0 6ES7 321-1BL00-9AM0
6ES7321-7BH01-0AB0 6ES7 321-1EL00-0AA0 6ES7 321-1FF01-0AA0 6ES7321-1FF10-0AA0
6ES7321-1FH00-0AA0 6ES7 321-1FH00-9AJ0
6ES7321-1CH00-0AA0 6ES7 321-1CH20-0AA0 6ES7 321-1BP00-0AA0
6ES7322-1BP00-0AA0
6ES7322-1BH01-0AA0 6ES7 322-1BH01-9AJ0
6ES7322-1BH10-0AA0 6ES7 322-1CF00-0AA0 6ES7 322-8BF00-0AB0 6ES7322-5GH00-0AB0 6ES7 322-1BL00-0AA0 6ES7 322-1BL00-9AM0
6ES7322-1FL00-0AA0 6ES7 322-1BF01-0AA0 6ES7 322-1FF01-0AA0 6ES7322-5FF00-0AB0 6ES7 322-1HF01-0AA0 6ES7 322-1HF01-9AJ0
6ES7322-1HF10-0AA0 6ES7 322-1HH01-0AA0 6ES7 322-1HH01-9AJ0
6ES7322-5HF00-0AB0 6ES7 322-1FH00-0AA0 6ES7 323-1BH01-0AA0 6ES7323-1BL00-0AA0 6ES7 323-1BL00-9AM0
开入模块(32点,24VDC)开入模块(32点,24VDC)组合件
(6ES7321-1BL00-0AA0+6ES7
392-1AM00-0AA0) 开入模块(16点,24VDC,诊断能力) 开入模块(32点,120VAC)开入模块(8点,120/230VAC) 开入模块(8点,120/230VAC)与公共电位单独连 接
开入模块(16点,120/230VAC)开入模块(16点,120/230VAC) (6ES7 321-1FH00-0AA0+6ES7
392-1AJ00-0AA0)开入模块(16点,24/48VDC) 开入模块(16点,48/125VDC) 光电隔离,每组 16,64 DI,DC24V,3MS,漏/源 光电隔离,每组 16,64 DO,DC 24V,0.3A(源),总电流2A/组 开出模块(16点,24VDC)开出模块(16点,24VDC)
(6ES7322-1BH01-0AA0+6ES7
392-1AJ00-0AA0)
开出模块(16点,24VDC)高速 开出模块(8点,48-125VDC) 开出模块(8点,24VDC)诊断能力开出模块(16点,24VDC,独立接点,故障保护) 开出模块(32点,24VDC)开出模块(32点,24VDC)
(6ES7322-1BL00-0AA0+6ES7 392-1AM00-0AA0) 开出模块(32点,120VAC/230VAC)开出模块(8点,24VDC,2A) 开出模块(8点,120V/230VAC) 开出模块(8点,120V/230VAC,独立接点)开出模块(8点,继电器,2A) 开出模块(8点,继电器,2A)
(6ES7322-1HF01-0AA0+6ES7 392-1AJ00-0AA0) 开出模块(8点,继电器,5A,独立接点)开出模块(16点,继电器)DO 开出模块(16点,继电器)
(6ES7322-1HH01-0AA0+6ES7 392-1AJ00-0AA0) 开出模块(8点,继电器,5A,故障保护)开出模块(16点,120V/230VAC) 8点输入,24VDC;8点输出,24VDC模块16点输入,24VDC;16点输出,24VDC模块 16点输入,24VDC;16点输出,24VDC模块 (6ES7323-1BL00-0AA0+6ES7 392-1AM00-0AA0)
Powered byTCPDF (www.tcpdf.org)
根据PLC输出端所带的负载是直流型还是交流型,是大电流还是小电流,以及PLC输出点动作的频率等,从而确定输出端采用继电器输出,还是晶体管输出,或品闸管输出。不同的负载选用不同的输出方式 ,对系统的稳定运行是很重要的。电磁阀的开闭、大电感负载、动作频率低的设备,PLC输出端采用继电器输出或者固态继电器输出;各种指示灯、变频器/数字直流调速器的启动/停止应采用晶体管输出。
2.3确定PLC编程工具 (1) 一般的手持编程器编程。 手持编程器只能用商家规定语句表中的语句表(STL)编程。这种方式效率低,但对于系统容量小、用量小的产品比较适宜,具有体积小、价格低、 易于现场调试等优点。这主要用于微型PLC的编程。 (2) 图形编程器编程。图形编程器采用梯形图(LAD)编程,方便直观,一般的电气人员短期内就可应用自如,但该编程器价格较高,主要用于微型PL C和中档PLC。 (3)计算机加PLC软件包编程
。这种方式是效率Zui高的一种方式,但大部分公司的PLC开发软件包价格昂贵,并且该方式不易于现场调试,主要用于中高档PLC系统的硬件组态和软件编程。