控制门关闭装置-地弹簧、闭门器建材CE认证标准
EN 1154:1996/A1:2002/AC:2006
Building hardware — Controlled door closing devices —Requirements and test methods
建筑五金-控制门关闭装置-要求和试验方法
Scope范围
This standard specifies requirements for controlled door closingdevices for swing doors, such devices being mounted on or in theframe, on or in the door, or in the floor .
此标准适用于被安装在旋转门上的闭门器, 闭门器可被安装在门框上,门上,或者在地板上。
The scope is limited to manually operated door closing deviceswhere the energy for closing is generated by the user upon openingthe door, such that when the door is released, it returns to aclosed position, in a controlled manner .
此标准于人力操作的闭门装置上, 关门的力来源于使用者推开门, 当门被释放时,门在被闭门器控制的状态下,回复到关闭状态。
Devices such as spting hinges, which do not exert a checkingcontrol during door closing, are outside the scope of thisstandard.
一些配置如弹簧饺链, 在整个关门过程中, 没有产生任何制动力, 这类配置不在本标准范围内。
Door closing devices ( door closers) manufactured in accordancewith this standard are recommended for use wherever there is arequirement for reliable closing control of a door
根据此标准生产的闭门器, 建议使用在需要保证关门控制的门上。
Door closers for use on fire/smoke doors need additionalattributes in order to contribute actively to meeting the essentialsafety requirements in case of fire , either independently or aspart of a complete door asse1nbly
适用于防火/烟门上的闭门器, 需要具备额外性能, 能独立, 或作为门的火险中基本的安全要求。
These additional requirements for door closers for use on afire/smoke door assembly are specified in normative annex A
这些适用于防火/烟门的闭门器, 其额外要求列在规范性附件 A 中。
Door closers incorporating electrically powered hold-openmechanisms , for use on fire/smoke door assemblies, are covered byprEN1155
包含电动保持开启机构的闭门器,用于防火/防烟门组件,由prEN1155覆盖
示例-闭门器/地弹簧
测试项目
Self-closing自锁 | Pass /Fail criteria for: Category of use: Angles of operation Power size: l Closingmoment l Openingmoment l Efficiency l Overloadperformance Suitability for fire/smoke door use: Fire/smoke door suitability Safety: l Closing time l Temperaturedependence l Fluid leakage l Damage l Latch control(when relevant) l Backcheck (whenrelevant) l Adjustableclosing force (when relevant) Zero position (when relevant) |
Durability of Self-closing 自锁耐久性 | Pass /Fail criteria for: Durability: number of test cycles 90度角门关闭测试500 000循环 双向门,每个方向90度角关闭测试250 000循环 Corrosion resistance: corrosion grade |
Dangerous substances 危险物质 | ZA.3 |
认证系统
系统1 System 1
制造商职责: | Factory production control (F.P.C)工厂生产控制; |
Further testing of samples taken at the factory 工厂取样测试 | |
Initial type testing初始型式测试; | |
NB机构职责: | Initial type testing初始型式测试; |
Initial inspection of factory and of F.P.C,工厂及FPC的初始检查 | |
Continuous surveillance, assessment and approval ofF.P.C. FPC的持续监督、评估和批准 |
EN 1154CE样板